GRAVITY SEWERS

Woodend Place Sanitary Sewer

Scope of work completed:

  • 6no. shafts of 5.5m internal diameter and depths of up to 12m installed in mixed ground conditions.
  • Installation of 570m of 1200mm sanitary sewer by Microtunnel with drive lengths ranging from 100m to 270m.
  • Low flow channel cast insitu after completion of tunneling.
  • Precast manholes and benching installed inside shafts.  
  • Tie in to existing live manhole at Pine Valley Drive